Click here for menu

How To Repair Pool Pump Not Working Hayward (Solved)

Home > Pool Pump > Pool Pump Not Working Hayward

Pool Pump Not Working Hayward

Contents

Check all breakers from inside the house to any subpanel the equipment is receiving power from. If power is reaching the time clock or switch, check the wires running from the switch to the pump for any signs of damage, and inspect the connections on each end, There may be a rattling as well caused by broken pieces of impeller within the housing. Smoking pump motors are usually caused by connecting 230V to a motor wired to receive only 115V. navigate here

If you have a cartridge filter, try priming the pump from the pool without the cartridge in place. TFP Expert who uses Pool School and my TF100 test kit along with PoolMath for my: Round 11K gallon AGP with deep end, 20" sand filter, Matrix 1hp 2spd, 6 2ftX20ft Pump only Runs for 5 seconds If your Hayward pump runs for only 5 seconds and shuts off, check the incoming voltage. Excess tightening will cause cracks in the frame and eventually form leaks.

Pool Pump Not Working Humming

First, start at poolside. Is there a solution to this or was the the end of our pump? If you’re concerned about weather effects, we suggest using the Universal Motor Cover to protect your investment.

Step 9 Leaks at unions on suction side - Check for leaks around the glued connection of the unions as above. These pumps must have a vacuum chamber, commonly known as a pump housing. In normal operation, air is being sucked into this hole. Pool Pump Making Loud Humming Noise If not then take it back apart and check and lube the o-ring.

The motor will automatically shut off before the motor generates enough heat to damage itself. Pool Pump Not Working Troubleshooting Jennies Garage 599,496 views 8:59 How To: Replace the Bearings in a Pool Pump Motor - Part I - Duration: 6:09. The skimmer weir, sometimes called the flapper, may be stuck in the up position, allowing air to mix with water in the suction line. If you just pulled the pump to check the impeller or replace a shaft seal, make sure the seal is installed correctly, and that diffuser and diffuser gaskets are seated firmly.

It is advisable not to locate any pool pump under someone's bedroom window. Pool Pump Capacitor Test The motor could be seized, the capacitorbad or a wire in the rear of the motor could be disconnected or otherwise shorted. You just lose water. × Comments Email Guide Print Guide See All Steps × Video Step by Step Top Step 1 Pool level too low - If the pool water level So i replaced the sand, replaced the jandy valve, replaced the lateral assembly and it still wont prime in either recirculate or filter mode.

  1. They can be replaced, but unless the motor is quite new, most pool owners will replace the entire motor.
  2. Self-priming can only occur when the pump has a diffuser.
  3. Step 4 Strainer basket clogged - Remove the strainer basket and clean debris out with a hose.
  4. Lubricate the O-ring with a silicon based lubricant.

Pool Pump Not Working Troubleshooting

If the pump is running off an extension cord, check that the cord is heavy enough to carry the voltage. They went ahead and gave me another motor, but the new one isn't working either. Pool Pump Not Working Humming should i be putting some silicone or plumpers thread anywhere on the screws or the impeller assemply to prevent this? Replacing Start Capacitor On Pool Pump Any ideas what is happening?

This is caused by a dirty or clogged filter, a blocked return line, or a valve that is shut off or partially shut on the return piping. http://brsgrp.com/pool-pump/pool-pump-not-working-right.html Swimming Pool Tips, Reviews & How To -MrDgvb1 123,089 views 13:36 Pool Motor - Humming-Loud Noise- Capacitor Replacement *UPDATE* - Duration: 4:31. If you feel anything unusual, remove the bolts to pull the motor out for a good cleaning of the impeller. Damage to the seal plate is usually caused by an over tightening of either the motor or housing bolts. Hayward Pool Pump Capacitor

You can achieve this using a drain king or pressurized air. Reply Matthew Simmons says: September 29, 2016 at 2:49 PM Jim - to figure this out, we will need more information about your pool upgrades. Also, some filtration systems may require up to 24-hours to clean your pool. his comment is here Like the area in your step 3 where the yellow sticker is.

If it's stuck, check that the impeller is not jammed with debris. Intex Pool Pump Won't Turn On Bad bearings are also a sign of a leaky shaft seal. Try the water drip test above.

Click OK to extend your time for an additional 30 minutes.

I turned the new pump on for the first time and the motor was running but there was no circulation of water. PureLine Prime October 31, 2016 Top Reasons an Above Ground Pool Needs Replacing October 28, 2016 Poolside Chat Episode #43: Finding The Right Spa Cover October 27, 2016 Archives November 2016 Your pump should be kept free of dirt and also located where it can be protected from flooding during heavy rain fall. Above Ground Pool Pump Problems What am I doing wrong?

Other components may have experienced freeze damage or warping. Any suggestions? Then make sure you supply voltage matches the voltage set up on your motor and that the connections are tight. weblink If the housing and a few other parts need replacing, it may be best to replace the whole pump.

Then check for problems with low water flow. The start capacitor is in the back of the motor under the cap. http://www.inyopools.com/HowToPage/how_ ...